ASHLY NXE8002

SKU : NXE8002

SGD 4,000.00
Availability: Out of stock

Network Power Amplifier, 2x800W @ 2-OHMS

SHARE THIS PRODUCT:

The nXe Series NXE8002 2-Channel 800W Power Amplifier with Programmable Outputs & Ethernet Control from Ashly is a Class-D switching amplifier combined with a switch mode power supply. This amplifier meets the requirements of demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces, and convention centers.

 

The rear panel has DIP switches for programming each channel output for either High-Z or Low-Z operation. This amplifier can be connected to a network with Ethernet control and features serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability, all controlled using the Protea Software Suite (not included).

 

Features:

 

  • 2-Channel high-output amplifier with programmable output on each channel (High-Z or Low-Z, selected via rear panel DIP switches)
  • Power-saving, Energy Management System with automatic <1W sleep-mode (defeatable)
  • Front panel power switch and level controls (can be disabled for security)
  • Rear panel DIP switches per channel for selection of high pass filter, limiter, input gain, and High-Z or Low-Z speaker output configuration
  • Remote DC level control on each input channel
  • Switch mode power supply automatically detects 120 or 240VAC operation
  • Extensive protection circuitry and continuously variable cooling fans
  • Multiple independent internal power supplies provide increased channel separation and reliability
  • Ethernet port for control and monitoring of amplifier functions, with front panel COM activity LED
  • Serial data port for use with Ashly remote control devices, or optional RS-232 converter for third party controllers (not included)
  • Protea software allows to remotely disable all front panel controls, including the on/ off switch, for a tamper-proof installation
  • Real-time clock with event scheduler
  • Instant standby mode that can be triggered by contact closure, software control, or event scheduler for reduced power consumption
  • Programmable power-on delay
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Aux preamp outputs, and fault condition logic outputs
  • Optional Cobranet or Dante network audio and AES3 digital audio input with pass-through
  • Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors
  • Neutrik speakON twist locking loudspeaker connectors for security, safety, and reliability
  • Neutrik powerCON detachable AC mains connector
  • Made in USA
Voltage Gain Selectable at 26, 32, or 38 dB, and 1.4 V 
Damping Factor >250 (8 Ω load <1 kHz)
Filter Input High Pass Filter: 80 Hz 2nd order
Distortion

<0.5% SMPTE, typical


<0.5% THD-N, typical (8 Ω, 10 dB below rated power, 20 Hz to 20 kHz)

Channel Separation -75 dB (dB from full output, 1 kHz)
Signal / Noise 20 Hz to 20 kHz, un-weighted
>108 dB
Frequency Response 20 Hz to 20 kHz, ±0.05 dB
Connector Balanced Input Connector: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
Input Impedance 10 kΩ
Maximum Input Level 21 dBu
Speaker Output Connector: Neutrik speakON
Network Control Network: Compatible with standard 100 MB Ethernet
AUX Outputs

Connector: Balanced Euroblock 3.5 mm


Maximum Output Level: 21 dBu

Contact Closure

Remote Standby: Euroblock 3.5 mm, close contact to GND for standby mode


Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall

Data Data Connection: Euroblock 3.5 mm - Gnd, 18 V, in, out
Outputs Fault Condition Logic Outputs: 4 x 3.5 mm Euroblock
Level Control Remote DC: 4 x 3.5 mm Euroblock - Gnd, CV, V+ per input
Attenuation

Front panel, software, offset link group, and remote per channel


Fully off = mute

Protection Circuits Inrush current limitation, temperature monitoring, output over-power protection, and mains fuses
Cooling Continuously variable temperature controlled axial fans
Environmental Non-condensing 32 to 113°F (0 to 45°C)
Power Requirements
Power

At 50 Hz 


Nominal (Automatic Sensing SMPS): 120 VAC


Operating Range: 70 to 135 VAC


Minimum Power-Up: 85 VAC

At 60 Hz


Nominal (Automatic Sensing SMPS): 240 VAC


Operating Range: 140 to 270 VAC


Minimum Power-Up: 170 VAC

Connector Power Cable Connector: 20 A powerCON
Maximum Output Power

Per Channel, Low-Z Output, All Channels Driven


2/4/8 Ω: 800 W

Output

Low Z Output, Bridge Mode, All Channels Driven: 1600 W (4/8 Ω)


70V, 100V Output, All Channels Driven: 800 W (70/100 V (per channel)

Power Draw

Sleep Mode: < 1 W


Standby Mode: 25 W


Idle (No Signal): 40 W 

Current Draw

For 120 VAC


Sleep Mode: 0.1 A


Standby Mode: 0.38 A


Idle (No Signal): 0.70 A

For 240 VAC


Sleep Mode: 0.05 A


Standby Mode: 0.19 A


Idle (No Signal): 0.35 A

 

Maximum, All Channels Driven, Typical Input


1/8 Max Power @ 2 Ω): 4.6 A for 120 VAC, 2.3 A for 240 VAC

Dissipation

Thermal Dissipation: Sleep Mode: <3.4 BTU/hr


Standby Mode: 85 BTU/hr


Idle (no signal): 136 BTU/hr


Typical (1 / 8 Max Power @ 2 Ω): 495 BTU/hr 

LED Indicators Front Panel LED Indicators

 

White: Power Switch: On, off, standby (flashing)

Red LED:


Clip / Mute Per Channel: Clip @ 1 dB below full output / mute


Protect: On (fault condition or shut down), Off

Green LED:


Signal Per Channel: -18 dBu, below rated output


Bridge Per Channel Pair: On, off


Com: On, for Ethernet data or device ID


Current Per Channel: Proportional to output

Yellow LED:


Temperature Per Channel: On dim at 90% maximum operating temperature, full bright + protect at 100%


Sleep: On, amplifier is asleep from audio inactivity


Disable: On, power switch & front panel attenuators are disabled

Dimensions (W x H x D) 19.0 x 3.5 x 16.8" (48.3 x 8.9 x 42.8 cm)
Weight 28.7 lb (13.1 kg)

 

Click here for full specs